OctudOCTUDBASFOfficial Ultrason® distributor
KOEN
Request a Quote
PARTS SUPPLY

PPSU & PEEK parts, made by Octud

Send the drawing and quantity — Octud handles grade selection, production with partner manufacturers and delivery. We work with ISO 9001, ISO 13485 and IATF 16949 certified moulders and specialists in medical and food-contact PSU/PPSU moulding. No moulder of your own required.

  1. 01Drawing & quantity
  2. 02Material & process review
  3. 03Partner quotation
  4. 04Prototype → production
What to send
Drawing (PDF + STEP) · quantity · service temperature & contact media · required certifications · current material
Where we work most
Medical devices · food-contact parts · semiconductor test sockets · electrolyser frames · fibre-optic connectors

Email the drawing instead: grit@octud.com

Send a drawing, get a quote

Reply within 24 hours. Drawings are used for quotation and manufacture only.

Drop drawing files here or click to selectPDF · STEP · IGES · X_T · DWG · DXF · images · ZIP — 50MB per file, up to 5 files
If the file is too large or upload fails · grit@octud.com

Principles

Partner criteria

ISO 9001, ISO 13485 or IATF 16949 certified, with dehumidifying dryers, hot-tool capability and annealing. Includes specialists in medical and food-contact PSU/PPSU moulding.

Tool ownership

Belongs to whoever paid for it. Storage and transfer terms on the quotation.

Quality responsibility

Octud is responsible to the customer. Inspection criteria agreed at prototype stage.

Confidentiality

Drawings used for quotation and manufacture only. NDA first on request.

If you already have a moulder

We support with resin, colorant and processing data only. We don't ask you to switch.

Questions

No. Octud owns material selection and processing review; manufacture is by partner shops with proven high-heat resin experience. To the customer, Octud is the single point for quotation, delivery and quality.

Yes. For small quantities we recommend machining from rod or plate first, then moving to moulding in the same grade once quantities are fixed.

Yes. We work with ISO 13485 certified partner moulders experienced in medical PSU/PPSU. Typical parts are instrument handles, trays and fluid components of diagnostic equipment that need repeated sterilisation; biocompatibility data (ISO 10993, USP Class VI) is supplied as manufacturer documentation per grade. Tell us the application, class and sterilisation method and we will confirm scope.

We work with moulders specialising in food-contact PPSU, PESU and PSU, and provide per-grade FDA 21 CFR 177 and EU 10/2011 declarations plus EU 2024/3190 (BPA) status with the quotation. Korean MFDS food-contact compliance is reviewed separately at finished-article level.

We'll help you find the right grade

Ask us for a TDS, pricing or a sample.

Request a Quote →FAQ